-40%

12V Digital Dual Relay Alarm Thermometer Temperature Controller Air Regulator

$ 3.39

Availability: 1085 in stock
  • Return shipping will be paid by: Seller
  • Brand: Unbranded/Generic
  • Item must be returned within: 60 Days
  • Refund will be given as: Money Back
  • All returns accepted: Returns Accepted
  • Country/Region of Manufacture: China
  • Condition: New
  • Type: 12V Temperature Control -20~100℃
  • MPN: Does Not Apply
  • EAN: Does Not Apply
  • UPC: Does Not Apply
  • Restocking Fee: No

    Description

    Visit store
    Items for sale
    About us
    Product Details
    Description
    12V Temperature Control -20~100℃ Precision Dual relay Alarm Air Regulator
    Description:
    Temperature range: -20 ℃ ~ + 100 ℃
    Resolution: -9.9 ℃ ~ 99.9 ℃ paragraph 0.1 ℃, other temperature ranges 1 ℃
    Temperature measurement accuracy: 1 ℃
    Minimum temperature difference: 0.1 ℃
    Refresh rate about: 0.5S
    Input Power: DC 12V
    Measuring input: 1 m NTC (10K 0.5%) alloy waterproof sensor
    Output: Two relay 10A
    Environmental requirements: -10 ℃ ~ + 60 ℃ Humidity 20% to 75%
    Size: 70mm * 39mm
    Intelligent dual temperature control relay instructions
    Tips: Set the temperature when the buyer must ensure that the upper limit temperature is greater than the lower limit temperature, the system will work properly.
    Circuit connection: Connect the power supply with reference to the circuit diagram and load, the temperature sensor is missing or damaged digital tube will show "- - -", before using buyer must check the temperature sensor is installed.
    The temperature output 10A relay, to meet a variety of high-power load, make sure that the line is correct.
    LEDs, LED status descriptions:
    LED: Off indicates the relay off, ON means the relay is closed
    Digital: Display "- - -", 1, check the temperature sensor 2 is missing or damaged, heating mode, high temperature protection 3, cryogenic cooling mode protection. In protected mode relay automatically disconnected.
    Use keys: temperature control panel has three buttons, button + button - SET button
    Button +: Achieving Rapid accumulation value
    Key: - fast diminishing value
    SET key SET: Temperature set temperature and operating mode interface query interface parameter setting interface
    During the SET press SET press according to different times, the corresponding digital temperature limit will be blinking, you can set the upper and lower temperature through the key addition and subtraction. After setting 8s automatically save data or short press three times data can be saved.
    SET Press to enter the actual temperature and the operating mode query interface, digital (on) the actual measured temperature. Digital (lower) showing the operation mode. L represents the lower limit temperature below the set temperature, H is the upper limit temperature is higher than the temperature setting, OFF indicates when the temperature is between the upper and lower limits, the relay is in the off state.
    Mode setting: Setting the temperature 1: temperature upper limit set temperature 2: lower limit temperature
    Example applications: now the upper limit temperature to 40.0 ℃, the minimum temperature is set to 20.0 ℃. At different temperature ranges relay operate as follows:
    When the actual temperature> 40 ℃, the relay 1 is closed, the relay 2 release;
    When the actual temperature of 20 ℃ ≤ ≤40 ℃ release relay 1, relay 2 release;
    When the actual temperature <20 ℃, the relay 2 is closed, the relay 1 release.
    Parameter settings: the need for the user parameter settings must first hold the SET button and then give the thermostat power, to enter the parameter setting interface. There are three sets of parameters P0-P2 can be used for user settings.
    Parameter setting item
    Function Description Setting range Factory setting
    P0 temperature correction -10 ℃ ~ + 10 ℃ 0
    P1 limit relay time 0 ~ 999s OFF
    P2 lower limit relay time 0 ~ 999s OFF
    friendly reminder:
    P1 = OFF: indicates the actual temperature exceeds the upper limit temperature, corresponding relay will remain energized (long attracted state).
    P1 = 1 ~ 999: indicates the actual temperature exceeds the upper limit temperature, corresponding relay will energize long, then stop (Jog attracted state).
    P2 = OFF: indicates the actual temperature is below the lower limit temperature, corresponding relay will remain energized (long attracted state).
    P2 = 1 ~ 999: indicates the actual temperature is below the lower limit temperature, corresponding relay will energize long, then stop (Jog attracted state).
    Package Inclued
    1PCS 12V Digital Dual Relay Alarm Thermometer Temperature Controller Air Regulator
    Payment Method
    Shipping Policy
    Returns & Refund Policy
    Feedback
    Payment Method
    EBAY Managed Payment.
    But we only
    Accept
    your
    Ebay Address
    , please Make sure it's 100% right.
    Payment must be received in 5 business days of auction closing.
    Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
    Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
    Shipping Policy
    1. We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.
    2. Orders will be processed instantly and dispatched within 1-3 business days except hoilday, so we do NOT accept any email/message note after you place orders.
    3. All package need to wait 30 days,Please take care it.Less than 30 days,we can't take a refund.
    Returns & Refund Policy
    All package need to
    wait 30 days
    (US only n
    eed 7-10 days)
    ,
    Please take care it.Less than 30 days,we can't take a refund
    .
    If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please keep in touch with us and double check the return address before you return it.
    If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.
    Feedback
    We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.