-40%

Digital 220V STC-1000 Temperature Controller Thermostat Regulator + NTC Sensor

$ 6.69

Availability: 24 in stock
  • Restocking Fee: No
  • Refund will be given as: Money Back
  • Select Model: STC-1000
  • Item must be returned within: 60 Days
  • Type: Temperature Controller
  • Relative humidity: 20~85% (No condensate)
  • Ambient temperature: 0℃~60℃
  • Brand: Unbranded
  • Accuracy: ±1℃(-50℃~70℃)
  • Analog/Digital: Digital
  • Return shipping will be paid by: Seller
  • EAN: Does not apply
  • UPC: Does not apply
  • Temperature measuring range: -50℃~99℃
  • Modified Item: No
  • Storage temperature: -30℃~75℃
  • Resolution: 0.1℃
  • Sensor error delay: 1 minute
  • contact capacity: Cool(10A/AC250V); Heat(10A/AC250V) Sensor: NTC 10K (1pce)
  • Select Product: AC 220V
  • Country/Region of Manufacture: China
  • Model: STC-1000/ STC-1000 Pro
  • Power Supply: AC110V~220V
  • MPN: Does not apply
  • Sensor Type: K
  • All returns accepted: Returns Accepted
  • Condition: New

    Description

    Home
    Arduino
    Module
    Sensor
    Chips
    About Us
    Main Instructing
    Switch the modes between cool and heat; Control temperature by setting the temperature setting value and the difference value; Temperature calibration. Refrigerating control output delay protection; Alarm when temperature exceeds temperature limit or when sensor error.
    Specification and Size
    Front panel size: 75(l)×34.5(w)mm
    Sensor length: 2M (include the probe)
    Product size: 75(l)×34.5(w)×85(h)mm
    Mounting size: 71(l)×29(w)mm
    Technical parameters
    Temperature measuring range:-50℃~99℃
    Resolution:0.1℃
    Accuracy:±1℃(-50℃~70℃)
    Sensor error delay: 1 minute
    Power supply: AC110V~220V
    Power consumption:<3W
    Relay contact capacity: Cool(10A/AC250V); Heat(10A/AC250V) Sensor: NTC 10K (1pce)
    Ambient temperature:0℃~60℃
    Storage temperature: -30℃~75℃
    Relative humidity:20~85% (No condensate)
    Display instruction:
    three-digit LED +Minus digit+ Status indicator light (Status indicator light(Cool, Heat)+Set indicator (Set)
    Key instruction:
    ”S”: the key to set; “▲”: Up key;”▼”: Down key; ” ”:the key to turn on and off the power
    Indicator light status instruction
    Indicator
    light
    Function
    Note
    Cool
    indicator
    light
    On: refrigeration starts;
    Off: refrigeration stops;
    flash: compressor delay
    Cool, Heat
    indicator light
    can not be
    “on” status
    simultaneously
    Heat
    indicator
    light
    On: heating starts;
    Off: heating stops;
    Set indicator
    light
    On: parameter setting status
    Key operation instruction
    1.The way to check parameter:
    Under normal working status, press and release”▲ ” key once instantly, it display temperature setting value; press and release” ▼ ” key once instantly, it displays the difference value. It back to display the normal temperature display status in 2s.
    2.The way to set parameter:
    Under controller normal working status, press ”S” key for 3s or more to enter parameter modifying mode, and the ”Set” indicator light on, screen display the first menu code”F1”. Press”▲” key to avoid the interference, the sensor down-lead and power wire should be kept a distance or “▼” key to page up and page down menu item to find accordingly code, press“S” key to display the parameter set value of the current menu. press and hold “S” key, press “▲” key or “▼” key again to adjust up and down the parameter setting value of the current menu item. Press and hold both “S” key and “▲” key or “▼”key simultaneously to choose and adjust the parameter value of the current menu value promptly. After finishing the setting, press and release the “  ” key instantly to save the parameter modified value and return to display the normal temperature value. If no key operation within 30 seconds, system won’t save modified parameter, screen back to display normal temperature. Screen display “Er” if error appears during parameter saving, and back to normal working status 3 seconds.
    3.Restore system data
    When electrified, system will check itself, screen will display “Er” if error exit, please press any key at this time, and it restore default value and enter into normal working mode. It is advised to reset the parameter value under this condition
    Operation instruction
    Under controller normal working status, press and hold “  ”key for 3s can turn off the controller; under controller “off” status, press and hold “  ” key for 3s can turn on the controller.
    Under the controller normal working status, screen display the current temperature value; also the controller can also switch the working mode between heating and cooling.
    Controller starts refrigerating with cool indicator light on when the measuring temperature≥temperature set value+ difference value, and the refrigerating relay is connected; the “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
    System starts heating when the measuring temperature value ≤the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; when the measuring temperature ≥ temperature set value , the “Heat” indicatorlight is off, and the heat relay disconnects.
    Menu instruction
    Code
    Function
    Set range
    Default
    F1
    Temperature set value
    -50℃~99℃
    10℃
    F2
    Difference set value
    1-10℃
    3℃
    F3
    Compressor delay time
    1-10 min
    3 min
    F4
    Temperature calibration value
    -10℃~10℃
    0℃
    Error description
    Alarm when sensor error: controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer, and the nixie tube display ”EE”, press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
    Alarm when he measuring temperature exceeds temperature measuring range: controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube display ”HH”, press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
    Safety regulations
    ★Danger
    1、Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong connections or overloading the relay.
    2、Dangers:prohibit connecting the wire terminals without electricity cut-off.
    ★Waring
    1、Prohibit using the machine under the environment of over damp, high temp, strong electromagnetism interference or strong corrosion.
    ★Notice
    1、The power supply should conform to the voltage value indicated in the instruction.
    2、To avoid the interference, the sensor down-lead and power wire should be kept a distance.
    Payment
    Shipping
    Refund
    Payment
    We accept PayPal only.
    But we only
    Accept
    your
    Ebay Address
    ,Please Make sure it's 100% right.
    Payment must be received in 5 business days of auction closing.
    Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
    Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
    Shipping
    Fill your shipping info
    Refund
    All package need to
    wait 30 days
    (US only n
    eed 7-10 days)
    ,
    Please take care it.Less than 30 days,we can't take a refund
    .
    If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it.
    If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.