-40%
Digital Display Thermostat SF-104 Temperature Controller Intelligent Regulator
$ 20.51
- Description
- Size Guide
Description
Digital Display Thermostat SF-104 Temperature Controller Intelligent RegulatorModel: digital thermostat (frozen) SF-104
Measuring temperature display range: -45 ~ 45oC
Measurement accuracy: ± 1 oC
Overall dimensions (mm): 77mm (length) x 35mm (width) x 60mm (D)
Working environment: -10 ~ 60 oC;
Relative Humidity: 20% to 90% (no condensation)
Temperature control, and an evaporator fan control
Defrost heating wire control
Automatic / manual electric defrost
Time / temperature terminated defrost
Compressor delay start
Compressor relay: 20A/1HP
Parameter lock, self-diagnosis
Key operation to restore the factory values
Suitable for air-cooled cryogenic freezers, cold storage
Temperature sensing probe: two, 2 meters long
Compressor: normally open 20A/250VAC
Defrost heating wire: normally open 10A/250VAC
Evaporator fan: normally open 5A/250VAC
Features
& Small type integrated intelligent control, direct control of 1P or less (including 1P) compressors.
& Temperature Display / Temperature Control / Manual, automatic defrost heater / evaporator fan control / time, temperature terminated defrost / Set Memory / Parameter Lock / self-diagnosis
Technical parameters
1, external sealed transformer output: AC 12V (a transformer can be equipped with a temperature controller)
2, the temperature probe: NTC, 2 amended (storage temperature, defrost control) 2 m long (regardless of sign)
3, the temperature display range: -45~ 66 oC (-45 ~ 150 oF) Accuracy ± 1oC (± 2 oF)
4, the control temperature range: -45 ~ 45 oC (-45 ~ 120 oF) Default: 0oC (32 oF)
5, Dimension: 77x35x60mm, hole size: 71x29mm
6, the working environment temperature: -10 ~ 60 oC (14 ~ 140 oF); relative humidity 20% ~ 90% (no condensation)
7, the relay contact capacity:
& Compressors: normally open 20A/250VAC (a compressor can be used directly over to pick AC contactor)
& Defrost heating wire: normally open 10A/250VAC (1KW load can be used directly over to pick AC contactor)
& Evaporator fan: normally open 5A/250VAC
Panel Operation
Press the "SET" 6 seconds to enter the parameter setting
Press the "defrost" button for 6 seconds, into defrost or stop defrost
Press the "UP" button 6 seconds defrost probe temperature display
E1 Lowest temperature: -45oC /-45oF ~ control the temperature,the factory value of -35oC /-31oF;
E2 Highest temperature: control temperature~45oC /120oF, the factory value of 20oC / 68oF;
E3 Temperature return difference: 1 ~ 10 oC / 1~18oF, the factory value of 4 oC / 7oF;
E4 Delay start-up time from 0 ~ 10minutes,the factory value of 2 minutes;
E5 Warehouse temperature probe calibration: -20 ~ 20 oC / -36 ~ 36oF , the factory value of 0 ;
E6 Defrost probe calibration: -20 ~ 20 oC / -36 ~ 36oF, the factory value of 0 ;
F1 Defrost time: 1~ 60 minutes, the factory value of 20 minutes;
F2 Defrost interval: 1 ~24 hours, the factory value of 6 hours;
F3 Defrost termination temperature: 0 ~40 oC / 32-104oF ,the factory value of 8 oC/46 oF
F4 Defrost temperature display: 0 = normal warehouse temperature display, 1 = defrost start temperature display;
F5 Fan Control,0 = compressor synchronization, 1 = has been running (defrost except)
C1 Temperature Units
0=Degrees Celsius
1=Degrees Fahrenheit
Function Description
1, temperature control
& Compressor after a brief delay, when the storage temperature is greater than (control temperature + temperature hysteresis), the compressor starts; storage temperature is less than the control temperature, the compressor stops.
& To protect the compressor, the compressor stops each time must be longer than the delay time (E4 parameters) to restart.
2, electric defrost function:
& Only defrost defrost termination probe temperature less than the temperature (F3 parameter) to enter when defrosting, turn the heating wire.
& Operating a defrost interval automatically enter the defrost state. If defrost defrost termination probe temperature is lower than the temperature, defrost indicator light, the compressor stops, the heating wire work, evaporator fan stops.
& When the defrost probe temperature is higher than defrost termination temperature; or time to defrost, then launch defrost, heating wire to stop working, after two minutes after drip into normal temperature patterns, such as the storage temperature is greater than (control temperature + temperature hysteresis) compressor starts, one minute after the evaporator fan is working.
& When the defrost interval is set to "00", canceled Automatic defrost function.
3, defrost locked storage temperature display:
When setting parameters F4 = 1, the lock in the project defrost inside temperature, shows defrost start temperature. After defrosting, storage temperature display delayed 20 minutes (or to control temperature) only after the return to normal display, delay the process of defrosting lights flashing.
4, non-normal operating mode:
& Thermostat probe short circuit or high temperature gauge (greater than 66/150) display "HH"; storage temperature probe open or low overrun (less than -45/-45) show "LL". Time to enter the timer mode, the compressor run for 30 minutes, stop for 15 minutes.
& Defrost probe short circuit, open circuit or overload, terminate defrost, limited only by the defrost time control.
Installation Precautions
1, in order to prevent high-frequency interference, the probe cable in conjunction with power lines or control line bundle, to separate the wiring. 12V low-voltage lines can not be parallel with the high-voltage wiring.
2, the probe should be installed head-on, the line down; defrost probe should be placed in a metal film evaporator where the thickest ice, and can not be close to the heating wire.
3, such as the installation requires, extend the probe line up to 100 m, without re-examination.
4, the thermostat can not install a drip place.
Packing list:
External transformer X1
Temperature probe X2
Mounting bracket X1
Baffle X1
Notice: Because,the international air shipping forbid to ship liquid,powder and batteries, If you purchased goods containing such items, we will not be putting them packing. Thank you for your support.
Payment must be made within 12 days after the auction/bid ends, or eBay will open Unpaid Item case automatically later.
Please read this before buying International Shipping may Be Delayed Due to Customs. Customers are Responsible For All Import Charges, Tariffs, Duties, Taxes, and Fees Associated with Import of the product. Shipping Charges does not include any Import Charges, Tariffs, Duties, Taxes, and Fees Associated with it. We are not responsible for undeliverable address.
We reserve the right to charge the shipping fee again for returned items due to wrong address.
Items are generally shipped within 10 business day after your payment has been cleared (Sat. & Sun. excluded.)
Dear friend, your happy is very important to me!.we stand behind every product we sell.Your bid is a contract - Place a bid only if you're serious about buying the item. If you are the winning bidder, you will enter into a legally biding contract to purchase the item. If payment is not received within 7 days, item may be offered to the next highest bidder or relisted at the seller's sole discretion.If you're not pleased with your purchase, we'll be happy to make an exchange or refund the product price less S&H within 7 days of your purchase. For any exchange or refund, we need the original receipt or a record of the purchase in our system, and the product must be in its original condition, including the box, packaging, and all accessories.Shipping and handling charges are not refundable.
We are professional EBAY sales team and lots of ebay buyers very satisfied with our services.You can enjoy top-quality product and high-quality services from us, Trust me that you will have a pleasant shopping experience in here.
Please contact us with any comments, questions or suggestions that you may have bysending ebay message, All the mail will be replied within 24 hours. Please ensure your mail box would not blocked / filtered our mails.we will be happy to assist you.please feel free to contact us for WHOLESALES deal,we will surely give you a satisfatory price.We would try our best to serve you with any question / problem. Please contact us first before leaving Negative / Neutral Feedback or open any cases.We work 6 Days a week From 9:00am - 6:00pm Monday - Saturday CHINA Time.