-40%

For OMRON E5CC-QX2ASM-800 Temperature Controller 100-240V AC New in Box

$ 20.69

Availability: 100 in stock
  • Brand: OMRON
  • Custom Bundle: No
  • Non-Domestic Product: No
  • Modified Item: No
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 30 Days
  • Model: E5CC-QX2ASM-800
  • Condition: New
  • Restocking Fee: No
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: Does Not Apply
  • Country/Region of Manufacture: China

    Description

    Item: OMRON Temperature Controller
    Type: E5CC-QX2ASM-800
    Condition: New
    Product Features:
    Input: Multi-Range
    Volts: 100-240VAC
    Frequency: 50/60Hz
    Package Include:
    1 x OMRON NEW E5CC-QX2ASM-800 100-240VAC DIGITAL TEMPERATURE CONTROLLER
    Item Specificati
    on:
    Power supply voltage
    A in model number: 100 to 240 VAC, 50/60 Hz
    D in model number: 24 VAC, 50/60 Hz; 24 VDC
    Operating voltage range
    85% to 110% of rated supply voltage
    Power consumption
    Models with option selection of 000:5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at
    24 VAC or 1.6 W max. at 24 VDC
    All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W
    max. at 24 VDC
    Sensor input
    Temperature input
    Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
    Platinum resistance thermometer: Pt100 or JPt100
    Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or
    140 to 260°C
    Analog input
    Current input: 4 to 20 mA or 0 to 20 mA
    Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
    Input impedance
    Current input: 150 O max., Voltage input: 1 MO min.
    (Use a 1:1 connection when connecting the ES2-HB/THB.)
    Control method
    ON/OFF control or 2-PID control (with auto-tuning)
    Control
    output
    Relay output
    E5CC-800:
    SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
    applicable load: 5 V, 10 mA
    E5CC-U-800:
    SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
    applicable load: 5 V, 10 mA
    Voltage output
    (for driving SSR)
    Output voltage: 12 VDC ?20% (PNP), max. load current: 21 mA, with short-circuit
    protection circuit
    Linear current
    output
    4 to 20 mA DC/0 to 20 mA DC, load: 500 O max., resolution: approx. 10,000
    Auxiliary
    output
    Number of outputs
    2
    Output
    specifications
    SPST-NO relay outputs, 250 VAC, Models with 2 outputs: 3 A (resistive load),
    Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V
    Event
    input
    Number of inputs
    2 or 4 (depends on model)
    External contact
    input
    specifications
    Contact input: ON: 1 kO max., OFF: 100 kO min.
    Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
    Current flow: Approx. 7 mA per contact
    Setting method
    Digital setting using front panel keys
    Indication method
    11-segment digital display and individual indicators
    Character height: PV: 15.2 mm, SV: 7.1 mm
    Multi SP
    Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key
    operations, or serial communications.
    Other functions
    Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm
    functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100%
    AT, MV limiter, input digital filter, self tuning, PV input shift, run/stop, protection
    functions, temperature status display, moving average of input value
    Ambient operating
    temperature
    -10 to 55°C (with no condensation or icing),
    for 3-year warranty: -10 to 50°C (with no condensation or icing)
    Ambient operating humidity
    25% to 85%
    Storage temperature
    -25 to 65°C (with no condensation or icing)
    Altitude
    2,000 m max.
    Recommended fuse
    T2A, 250 VAC, time lag, low shut-off capacity
    Installation environment