-40%
For OMRON E5CC-QX2ASM-800 Temperature Controller 100-240V AC New in Box
$ 20.69
- Description
- Size Guide
Description
Item: OMRON Temperature ControllerType: E5CC-QX2ASM-800
Condition: New
Product Features:
Input: Multi-Range
Volts: 100-240VAC
Frequency: 50/60Hz
Package Include:
1 x OMRON NEW E5CC-QX2ASM-800 100-240VAC DIGITAL TEMPERATURE CONTROLLER
Item Specificati
on:
Power supply voltage
A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range
85% to 110% of rated supply voltage
Power consumption
Models with option selection of 000:5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at
24 VAC or 1.6 W max. at 24 VDC
All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W
max. at 24 VDC
Sensor input
Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or
140 to 260°C
Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance
Current input: 150 O max., Voltage input: 1 MO min.
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method
ON/OFF control or 2-PID control (with auto-tuning)
Control
output
Relay output
E5CC-800:
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
applicable load: 5 V, 10 mA
E5CC-U-800:
SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
applicable load: 5 V, 10 mA
Voltage output
(for driving SSR)
Output voltage: 12 VDC ?20% (PNP), max. load current: 21 mA, with short-circuit
protection circuit
Linear current
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 O max., resolution: approx. 10,000
Auxiliary
output
Number of outputs
2
Output
specifications
SPST-NO relay outputs, 250 VAC, Models with 2 outputs: 3 A (resistive load),
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V
Event
input
Number of inputs
2 or 4 (depends on model)
External contact
input
specifications
Contact input: ON: 1 kO max., OFF: 100 kO min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Setting method
Digital setting using front panel keys
Indication method
11-segment digital display and individual indicators
Character height: PV: 15.2 mm, SV: 7.1 mm
Multi SP
Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key
operations, or serial communications.
Other functions
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm
functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100%
AT, MV limiter, input digital filter, self tuning, PV input shift, run/stop, protection
functions, temperature status display, moving average of input value
Ambient operating
temperature
-10 to 55°C (with no condensation or icing),
for 3-year warranty: -10 to 50°C (with no condensation or icing)
Ambient operating humidity
25% to 85%
Storage temperature
-25 to 65°C (with no condensation or icing)
Altitude
2,000 m max.
Recommended fuse
T2A, 250 VAC, time lag, low shut-off capacity
Installation environment
Installation Category II, Pollution Class 2 (IEC 61010-1 compliant)