-40%

Microcomputer Thermostat Switch Temperature Controller DC 12V Digital Display

$ 5.71

Availability: 61 in stock
  • Item must be returned within: 60 Days
  • Input Voltage: DC12V
  • Condition: New
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • MPN: Does Not Apply
  • Refund will be given as: Money Back
  • Brand: Unbranded
  • Output: 20A Relay

    Description

    Microcomputer Thermostat Switch Temperature Controller DC 12V Digital Display
    Features:
    This delicate digital display temperature controller can set Celsius mode or Fahrenheit mode.
    The ambient and set temperature precision
    is 0.1℃. It is convenient to install and wiring is simple.
    Wide temperature measurement range from -50℃ to 110℃ and supports high temperature protection.
    Can be installed directly or embedded in industrial control equipment panel, convenient and quick.
    Widely used in the hatching area, equipment case, air conditioning system, temperature control protection and other fields.
    Specification:
    Input Voltage:
    DC12V
    Temperature Measurement Range: - 50℃~110 ℃
    Resolution Ratio: -9.9℃-99.9℃--0.1℃  other temperature intervals--1℃
    Measurement Precision: 0.1 ℃
    Control Precision: 0.1 ℃
    Return Difference Precision: 0.1 ℃
    Refresh Rate: 0.5 S
    High-temperature Protection: 0-110 ℃
    Measurement Input: NTC (10K 0. 5%) waterproof sensor
    Output: 20A Relay
    Environmental Requirements:
    Temperature Requirement: -10 ℃~60 ℃
    Humidity Requirement: 20%-85%
    Machine Power Consumption: static current ≤ 35MA, pickup current ≤ 65MA
    Weight: 33g / 1.2oz (approx.)
    Package list:
    1 * Temperature Controller
    Methods of Use:
    After Connecting to the power supply and load (referring to the wiring diagram), you can supply power for the controller, the color red manifest for measuring temperature, the following color blue (or red) as required to set the temperature
    In the case of manifesting real temperature and please press the button set, the following setting text digital will flash and temperature, after completing the setting, please wait for 3 it will return automatically, at this time controller will automatically disconnect Relay according to the preset temperature, the this senor can meet all kinds of large power load, please make sure the line is correct
    The Description of Light and Digital Tube Status:
    Light: The off means Relay is disconnected, and the normal light on shows that the Relay has closed.
    Digital tube: The sign LLL is the open circuit of sensor and the sign HHH means beyond the measuring range, the controller will forcibly disconnect Relay, the sign --- means high- temperature protection
    The Description of Parameters Function:
    Please press the button SET five seconds and then it can enter to the main menu of setting, pressing STC(+)and C/F (-) can switch to P0-P8.
    About the adjustment of parameters P0-P8, when you need to adjust P0, firstly please press STC (+) and C / F (-) at the same time, and the P0figurewill flash, secondly please press STC (+)and C / F (-) to adjust, if done, finally please press STC (+) and C / F (-) to confirm at the same time,P1-P8 which can be set the parameters of each code like P0according to the needs of their own.
    The key C/F is a key for switching Fahrenheit or Celsius
    Press the key C/F once, and it will manifest F(Fahrenheit mode),and then press the key C/F once, it will show C(Celsius mode), the default mode is C(Celsius mode),if there is a big temperature error when you use it, maybe it is F mode.
    An example for setting:
    If you need to Control the refrigeration equipment
    1: Please set into C mode in the code P0:
    2:In the case of manifesting the actual temperature you should press the key SET, and the following digital of setting text will flash, then press C/F (+) and SET (-) to set the stop cooling temperature, after setting please wait for 3 seconds, it will automatically confirm to return.
    3:Return difference setting: Firstly please press the key SET for five seconds all the time, and it will enter the setting main menu, secondly press STC (+)and C / F (-) to switch into P1, when switching into P1,please press STC (+) and C / f (-)once at the time, the P0figure will flash, then please press STC(+)and C / f (-)to set to difference value(return difference means that you should add several degrees to start, for instance, if the it stops when the stop setting temperature is 25 degrees, you should need to set the cooling temperature to 28 degrees, the value in the code P1should be set 3 degrees, so the return difference value is 3 degrees),after finishing that, finally please press STC(+) C/F (-) at the same time to confirm.
    4:The above steps are set up, the data is automatically saved, and the final result is, in the control of refrigeration equipment, higher than28 degrees to start the refrigeration, refrigeration to 25degrees to stop.
    If you need to control the heating equipment:
    1: Please set into H mode in the code P0.
    2:In the case of manifesting the actual temperature you should press the key SET, and the following digital of setting text will flash, then press C/F (+) and SET (-) to set the stop heating temperature, after setting please wait for 3 seconds, it will automatically confirm to return.
    3:Return difference setting: Firstly please press the key SET for five seconds all the time, and it will enter the setting main menu, secondly press STC (+) and C / F (-) to switch into P1,when switching into P1, press STC (+) and C / f (-) once at the time, theP1figure will flash, then please press STC (+) and C / f (-) to set to difference value(return difference means that you should add several degrees to start, for instance, if the it stops when the stop setting temperature is 25 degrees, you should need to set the heating temperature to 22 degrees, the value in the codeP1should be set 3 degrees, so the return difference value is 3 degrees),after finishing that, finally please press STC (+) C/F (-) at the same time to confirm.
    4:When the above steps all are set up,the data are automatically saved ,so as controlling the heating equipment, it will start heating system less than 22 degrees, and it will stop heating when the temperature is 25 degrees.
    Code
    Explain
    Setting range
    Factory setting
    P0
    Heating/cooling
    H/C
    C
    P1
    Return difference
    0.1-30
    2.0
    P2
    Set limit maximum
    + 110
    110
    P3
    Set limits to the minimum
    -50
    -50
    P4
    Temperature correction
    -15-15
    0
    P5
    Delay start
    0-10
    0
    P6
    High temperature alarm
    -50~110
    OFF
    P7
    CS/FH
    cs
    F8
    Factory Reset
    ON-OFF
    OFF
    We accept PayPal only.
    We only ship item to your PayPal verified address.
    Payment must be received within 3 days from the date of purchase.
    Orders will be processed instantly and dispatched in same day normally, so we do NOT accept any Email/Message note after you place orders.
    All the items will be dispatched within one business day by Airmail after the payment is clear.
    Most times you will receive your order within 10-30 business days after we transfer your package to the delivery company. We cannot guarantee the delivery timeframe if the post office has any unexpected delays due to holiday, weather, customs, or other conditions. Some countries like Russia, Brazil, or some European countries may take up to 50 days or longer for delivery.
    We appreciate your patience if you haven't received items in 30 days(Russian customers may need more patience by reason of the local delivery system and/or customs). If you are concerned in any way, please feel free to contact us via ebay message
    instead of leaving negative/neutral feedback or opening a dispute
    .
    We will make every effort to fix any problem(resend or refund any missing item).
    Customs duty is obligation and liability of
    citizen
    s in your country, so buyer should be responsible for any tax and custom duty incurred. Generally, the delay or failure delivery is sometimes caused by the policy of different customs.
    1. Our listing price includes the value of goods,packaging cost,and export
    taxes,not including international import duties.
    2. Import duties,taxes,and charges are not included in the item price or shipping fee.
    3.
    T
    he import duties are buyers' responsibility
    .Please check with your country's
    customs office determine what these additional costs will be prior to your
    purchase.
    4. All disputes arising from the import duties will be submitted to ebay for solution.
    1. Any questions,
    pls. contact us via ebay message or email us.
    We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. post a message again because sometimes our message system may block some emails.
    2. If you are satisfied with our service, pls. kindly leave us a positive feedback and give us the Detailed Seller Rating with all "
    5 stars
    " in very area
    3. Our aim is to provide Top Level Customer Service, your recognition will encourage us greatly and serve you better.
    We strive to keep all our customers satisfy.
    4. We greatly appreciate your POSITIVE feedback.
    Please do NOT leave negative feedback without asking for help.
    Thanks!
    We will always do our up most to exceed your expectations in customer service, communication and dispatching of your orders.