STC-3008
Power supply: DC12V DC24V AC 110-220V
● Measurement temperature range: -55 ° C ~ +120 ° C
● Resolution: 0.1
● Accuracy: ±1 °C
● Relay output contact capacity: heating: 10A/240VAC, cooling: 10A/240VCA
● Sensor h type: imported NTC sensor, line length 1 meter
● Shell material: gray ABS flame retardant plastic shell
Set startup temperature:
Press the "up" button once to display the starting temperature. Long press the "up" button for about 3 seconds,The required temperature can be set by the up and down keys
Set the stop temperature:
Press the button once to display the stop temperature. Long press the button for about 3 seconds and the stop temperature number flashes. The required temperature can be set by the up and down keys
Press "Up 1" Button & "Up 2"Button at the same time to setting mode
Code
Function
Set Range
Default
P0
Compressor 1 delay time
0-60min
0min
P1
Compressor delay time
0-60min
0min
P2
High temperature alarm value
55-120° C
120°C
P3
Low temperature alarm value
55-120° C
-55°C
How to restore factory Settings
Press the "Down 1" and "Down 2" button at the same time, the factory setting is restored
Package Content:
1x Temperature Controller
STC-3018
Description:
● Power supply: 110-220VAC ± 10%, 50/60Hz (or DC12V / DC24V)
● Measurement temperature range: -50°C ~ +120°C / -58°F~248°F
● Resolution: 0.1°C
● Accuracy: ±1°C
● Relay output contact capacity: heating: 10A/240VAC, cooling: 10A/240VCA
● Sensor h type: imported NTC sensor, line length 1 meter
● Shell material: gray ABS flame retardant plastic shell
● Net weight 120g, Gross weight 140g
Instruction:
Normal mode: The red digital tube on the left shows the real-time temperature, the blue digital tube on the right shows the set temperature.
Setting mode: The red digital tube on the left displays the setting mode, the blue digital tube on the right displays the setting contents.
Code Instruction:
Code
Function
Default
Set Range
Start or Stop Temperature
0°C/68°F
-50~120°C/-58~248°F
P0
Working mode
H
H/C
P1
Difference set value
2
0.2-10
P2
High temperature alarm value
80°C/176°F
-50~120°C/-58~248°F
P3
Low temperature alarm value
-50°C/-58°F
-50~120°C/-58~248°F
P4
Temperature calibration value
0
-10.0°C~10.0°C
P5
Compressor delay time
0
0-60Min
P6
Display mode
C
C/F
P0: working mode
This setting is mainly set to the value when the thermostat is used for the first time. If it is used for heating, it should be set to H. If it is used for cooling, it should be set to C.
P1: hysteresis setting
The hysteresis is the difference required when the thermostat reaches the set temperature and stops working again. For example, if we set the heating mode to a temperature of 37-40 degrees, then the difference is 3
P2: high temperature alarm value
When the temperature reaches the set value, there will be an alarm action and stop working.
P3: low temperature alarm value
When the temperature is lower than the set value, there will be an alarm action and stop working.
P4: temperature correction
These functions are used for temperature calibration. If there is a deviation between the detected temperature and the actual temperature, some functional effects can be used. The positive value = measured value + corrected value. For example, we measure the temperature at 25.6 degrees and actually 25.8 degrees. P4 can be used. Set to 0.2 then the final temperature is 25.6+0.2=25.8
P5: delayed start
This function is generally used for compressor refrigeration. If you purchase some thermostats for the refrigerator freezer, this value must be set. According to the compressor back pressure, the general setting is 3-6 minutes.
P6: C/F conversion
If you want to change to F value, change the unit to F, the unit display light is on. If you want to change it to C value, change the unit to C, the unit display light is not bright. If you want to convert quickly, exit the display, long press You can quickly convert units by adding 3 seconds.
Package Included:
1 x
12V / 24V / 110V-220V
Temperature Controller+Waterproof Sensor
STC-3028
Description
:
● Relay output contact capacity: 10A
● Integrated sensor, line length 1 meter
● Shell material: gray ABS flame retardant plastic shell
● Net weight 120g Gross weight 140g
Package Content:
1 x Temperature Controller
Shipping Policy
Payment Method
Returns Policy
Shipping Policy
Payment Method
Returns Policy
Home
Payment
Shipping
About us
Contact us
Copyright©2018 datacaciques
Home
Payment
Shipping
About us
Contact us
Store Categories
Store Categories
Other
Product View
Details
STC-3008
Power supply: DC12V DC24V AC 110-220V
● Measurement temperature range: -55 ° C ~ +120 ° C
● Resolution: 0.1
● Accuracy: ±1 °C
● Relay output contact capacity: heating: 10A/240VAC, cooling: 10A/240VCA
● Sensor h type: imported NTC sensor, line length 1 meter
● Shell material: gray ABS flame retardant plastic shell
Set startup temperature:
Press the "up" button once to display the starting temperature. Long press the "up" button for about 3 seconds,The required temperature can be set by the up and down keys
Set the stop temperature:
Press the button once to display the stop temperature. Long press the button for about 3 seconds and the stop temperature number flashes. The required temperature can be set by the up and down keys
Press "Up 1" Button & "Up 2"Button at the same time to setting mode
Code
Function
Set Range
Default
P0
Compressor 1 delay time
0-60min
0min
P1
Compressor delay time
0-60min
0min
P2
High temperature alarm value
55-120° C
120°C
P3
Low temperature alarm value
55-120° C
-55°C
How to restore factory Settings
Press the "Down 1" and "Down 2" button at the same time, the factory setting is restored
Package Content:
1x Temperature Controller
STC-3018
Description:
● Power supply: 110-220VAC ± 10%, 50/60Hz (or DC12V / DC24V)
● Measurement temperature range: -50°C ~ +120°C / -58°F~248°F
● Resolution: 0.1°C
● Accuracy: ±1°C
● Relay output contact capacity: heating: 10A/240VAC, cooling: 10A/240VCA
● Sensor h type: imported NTC sensor, line length 1 meter
● Shell material: gray ABS flame retardant plastic shell
● Net weight 120g, Gross weight 140g
Instruction:
Normal mode: The red digital tube on the left shows the real-time temperature, the blue digital tube on the right shows the set temperature.
Setting mode: The red digital tube on the left displays the setting mode, the blue digital tube on the right displays the setting contents.
Code Instruction:
Code
Function
Default
Set Range
Start or Stop Temperature
0°C/68°F
-50~120°C/-58~248°F
P0
Working mode
H
H/C
P1
Difference set value
2
0.2-10
P2
High temperature alarm value
80°C/176°F
-50~120°C/-58~248°F
P3
Low temperature alarm value
-50°C/-58°F
-50~120°C/-58~248°F
P4
Temperature calibration value
0
-10.0°C~10.0°C
P5
Compressor delay time
0
0-60Min
P6
Display mode
C
C/F
P0: working mode
This setting is mainly set to the value when the thermostat is used for the first time. If it is used for heating, it should be set to H. If it is used for cooling, it should be set to C.
P1: hysteresis setting
The hysteresis is the difference required when the thermostat reaches the set temperature and stops working again. For example, if we set the heating mode to a temperature of 37-40 degrees, then the difference is 3
P2: high temperature alarm value
When the temperature reaches the set value, there will be an alarm action and stop working.
P3: low temperature alarm value
When the temperature is lower than the set value, there will be an alarm action and stop working.
P4: temperature correction
These functions are used for temperature calibration. If there is a deviation between the detected temperature and the actual temperature, some functional effects can be used. The positive value = measured value + corrected value. For example, we measure the temperature at 25.6 degrees and actually 25.8 degrees. P4 can be used. Set to 0.2 then the final temperature is 25.6+0.2=25.8
P5: delayed start
This function is generally used for compressor refrigeration. If you purchase some thermostats for the refrigerator freezer, this value must be set. According to the compressor back pressure, the general setting is 3-6 minutes.
P6: C/F conversion
If you want to change to F value, change the unit to F, the unit display light is on. If you want to change it to C value, change the unit to C, the unit display light is not bright. If you want to convert quickly, exit the display, long press You can quickly convert units by adding 3 seconds.
Package Included:
1 x
12V / 24V / 110V-220V
Temperature Controller+Waterproof Sensor
STC-3028
Description
:
● Relay output contact capacity: 10A
● Integrated sensor, line length 1 meter
● Shell material: gray ABS flame retardant plastic shell
● Net weight 120g Gross weight 140g
Package Content:
1 x Temperature Controller
Shipping Policy
Payment Method
Returns Policy
Shipping Policy
We will arrange shipping for you within 24 Hours after payment cleared except the holidays.
-We ship items to Worldwide. Thank you!
-we will ship out the order in 1-2 business days after payment cleared .Since it is international shipping ,delivery time is about 15--28 business days to arrive to most countries.
Payment Method
We accept PayPal payment ONLY, and must be received within 5 days from the date of purchase.
2. It is easy and safe for you to pay by credit cards, debit cards, bank transfers and PayPal account balances.
3.Buyers are responsible for import duties,custom fees and taxes, if any, please check your country.
Returns Policy
1.We believe our items are so outstanding. We are convinced you will be happy with your Purchase.
2. If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund or resend the item to you after the returned item arrived at our warehouse.
3. Please include your eBay ID and item number with any email requests.