Specfications:
● Power supply: DC12V
● Measurement temperature range: -50°C ~ +120°C / -58°F~248°F
● Resolution: 0.1°C
● Accuracy: ±1°C
● Relay output contact capacity: heating: 10A/240VAC, cooling: 10A/240VCA
● Sensor h type: imported NTC sensor, line length 1 meter
● Shell material: gray ABS flame retardant plastic shell
● Net weight 120g, Gross weight 140g
Instruction:
Normal mode: The red digital tube on the left shows the real-time temperature, the blue digital tube on the right shows the set temperature.
Setting mode: The red digital tube on the left displays the setting mode, the blue digital tube on the right displays the setting contents.
Code Instruction:
Code
Function
Default
Set Range
Start or Stop Temperature
0°C/68°F
-50~120°C/-58~248°F
P0
Working mode
H
H/C
P1
Difference set value
2
0.2-10
P2
High temperature alarm value
80°C/176°F
-50~120°C/-58~248°F
P3
Low temperature alarm value
-50°C/-58°F
-50~120°C/-58~248°F
P4
Temperature calibration value
0
-10.0°C~10.0°C
P5
Compressor delay time
0
0-60Min
P6
Display mode
C
C/F
P0: working mode
This setting is mainly set to the value when the thermostat is used for the first time. If it is used for heating, it should be set to H. If it is used for cooling, it should be set to C.
P1: hysteresis setting
The hysteresis is the difference required when the thermostat reaches the set temperature and stops working again. For example, if we set the heating mode to a temperature of 37-40 degrees, then the difference is 3
P2: high temperature alarm value
When the temperature reaches the set value, there will be an alarm action and stop working.
P3: low temperature alarm value
When the temperature is lower than the set value, there will be an alarm action and stop working.
P4: temperature correction
These functions are used for temperature calibration. If there is a deviation between the detected temperature and the actual temperature, some functional effects can be used. The positive value = measured value + corrected value. For example, we measure the temperature at 25.6 degrees and actually 25.8 degrees. P4 can be used. Set to 0.2 then the final temperature is 25.6+0.2=25.8
P5: delayed start
This function is generally used for compressor refrigeration. If you purchase some thermostats for the refrigerator freezer, this value must be set. According to the compressor back pressure, the general setting is 3-6 minutes.
P6: C/F conversion
If you want to change to F value, change the unit to F, the unit display light is on. If you want to change it to C value, change the unit to C, the unit display light is not bright. If you want to convert quickly, exit the display, long press You can quickly convert units by adding 3 seconds.
Package Included:
1 x Temperature Controller
Payment
Shipping
Refund
Payment
We accept PayPal only.
But we only
Accept
your
Ebay Address
,Please Make sure it's 100% right.
Payment must be received in 5 business days of auction closing.
Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
Shipping
Fill your shipping info
Refund
All package need to
wait 30 days
(US only n
eed 7-10 days)
,
Please take care it.Less than 30 days,we can't take a refund
.
If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it.
If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.