USB PID TEMPERATURE CONTROLLER,W/ 32 RAMP & 32 SOAK STEPS, RELAY OUTPUT
$ 58.06
- Description
- Size Guide
Description
This ramp soak PID controller with computer access can be used to control external relay/contactor, solid state relay (SSR), or control a small AC load directly. This listing includes USB adapter and control software (Windows OS computer is required), so user can get access to this PID via his computer.This model has a built-in relay that can handle 10 A of current at 120VAC.
That means 1200 watts of load can be connected directly to the controller without the need of an external relay or SSR. That is a very convenient for applications in which only a small heater is used. It can also be used to drive external relays or mechanical contactors.
Software Tutorial Video
:
MOBILE USERS:
copy/paste this video link into a web browser
https://youtu.be/
zhTCAy6q7Dc
Features
32 programmable ramp steps and 32 programmable soak steps (total of 64 segments)
Single step mode for single point temperature control
Windows OS based control software and USB adapter are included
PID control with fuzzy logic enhancement
Dual alarm outputs
0.2% accuracy over the entire input range
Displays in either Fahrenheit or Celsius temperature unit
Minute/second step timer
High brightness, large LED display easily read from distance
Manual, US-based technical support and 90-days warranty
This is a brand new, dual display, 1/16 DIN (48 x 48 mm) programmable PID temperature/process controller. This controller is for applications where it is desirable to have an adjusted set point automatically over time. Up to 64 steps can be programmed into this controller, including 32 ramp steps to ramp the temperature up & down at controlled rate, and 32 soak steps to maintain the temperature for a specific period time. The step timer unit can be set as minute or second. This controller also has single step mode. This feature will disable ramp soak settings, so this controller will function like a single set point standard PID controller (like SYL-2342/SYL-2352).
This listing includes one PID controller, one USB adapter*, one 6ft data cable, Windows based control software** and US support.
User can use his Windows PC (not included) to monitor and adjust the settings via USB adapter.
* The default USB adapter option is not AC insulated. Please be careful when you connect this data cable from the PID to USB adapter. If high voltage is applied on this data cable by mistake, high voltage will damage this USB adapter and your connected computer. For better protection, optional AC insulated USB adapter is offered and recommended. It can protect your computer from high voltage damage.
** macOS/Linux is currently not supported. Communication protocol is standard modbus-RTU.
This PID controller has two alarm relay outputs. Alarm 1 is a temperature alarm. It can be activated by the temperature set point (absolute high/low alarm, relative high/low alarm, etc). Alarm 2 is a program ending alarm. Once the program is completed, this alarm can be turned on for a specific duration time, to drive a buzzer or indicator.
User can use Auber PID software to monitor the current controller status, check record plot, record data, download new program and more. See key features below:
Check and edit all the parameter settings.
Edit and store multiple ramp soak programs with customized project names. Easily transfer your new program to the PID.
Monitor and record your temperature trace. Export to spreedsheet file or plot file.
Monitor multiple PIDs at same page
Main Specifications
SYL-5342PA
Programming Step Number
32 Ramp Steps + 32 Soak Steps
Minimum Ramp Rate
0.1°C/min or 144°C/day
Ramp Rate Resolution
0.1 degree/min increment*
Input type
TC: K, E, J, T, S, R
RTD: Pt100, Cu50
Display
Two lines, Four digits. °F or °C.
Display Resolution
1°C/°F or 0.1°C/°F
Accuracy
±0.2% or ±1 unit of full input range
Control mode
Fuzzy PID, On-Off
Output mode
Relay w/ NO and NC
contacts: 7A at 240VAC,
10A at 120VAC, or 10A at 24VDC
Alarm
Process high/low alarm, deviation high/low alarm
Alarm output
Relay contact (Resistive): 1A at 240VAC, 3A at120VAC, or 3A at 24VDC
Power supply
voltage rating
85~240VAC/50~60Hz
Overall dimension
1.89 x 1.89 x 3.94" (48 x 48 x 100 mm)
Mounting cutout
1.77 x 1.77" (45 x 45 mm), 1/16 DIN
*To achieve high ramp rate resolution (<0.1 degree/min), user can use RS485 protocol to update SV in a certain period of time. See RS485 supplementary manual for details.